Master Ring

Izajes » Productos » Master Ring

As always, our Products are here to strengthen your Company.

Master Ring

Code TH47

 

TA 47 Anilla Master

REFMaterial DiameterMWL 4:1 TonsUseful Width UWUseful Length LUUseful Width UWXUseful LU
WA47-20/1320 mm5,509516060110
WA47-22/1622 mm6,659516080140
WA47-26/2026 mm9,4011019095160
WA47-32/2632 mm14,20130230110190
WA47-38/3038 mm22,30150275130230
WA47-45/3245 mm33,50180340130230
WA47-50/3850 mm40,80190350150275
WA47-56/4556 mm56,80200400180340

Recommendations

Unwinding

The coil should be breaked while unwinding so that the wire rope comes out with a certain pressure and does not turn on its axis. This prevents bumps and kinks. If the coil is not equipped with brakes, then an operator should stop it..

Cables de Acero

Transport between coils

When the wire rope is carried from a full coil to an empty one or to a machine drum, this should be done from the upper or lower part of both, but never from the upper part of one coil and the lower part of the other, or vice versa.

Cables de Acero

Wire rope winding

The wire rope winding on the machine drum must be carried out correctly so that there are no spires overlapping and cross-linking, which would crush and distort the cords. The following figures represent the four cases that could effectively take place:

  1. Right torsional wire winding at the upper part of the drum.
    The mooring point should be located on the left side of the drum.
  2. Right torsional wire winding at the lower part of the drum.
    The mooring point should be located on the right side of the drum.
  3. Left torsional wire winding at the lower part of the drum.
    The mooring point should be located on the right side of the drum.
  4. Left torsional wire winding at the lower part of the drum.
    The mooring point should be located on the left side of the drum.

We do not recommend winding the wire around the drum in several layers, but if so, this technique is applied for the first layer of winding.

Cables de Acero

Deflection angle

The deflection angle is that formed by the wire from the first fixed pulley on the edge of the winding drum. It should not exceed 1º 30'.

Cables de Acero

Wire cutting

Cutting with shears or scissors. Before cutting, wires are to be tied together on both sides of the cutting area. The number of ties, the width and the distance between them depend on the wire diameter (see table). It is key to avoid longitudinal tilts among the different cord layers, since, in that case, those which have moved the least will bear the greatest part of the load, and there is the risk of breakage.

Cables de Acero
Tie characteristics
Wire rope diameterNo. of ties
on each side
of the cut
Tie
length
Distance
between ties
Wire diameter
rec. iron piece to be
used (mm)
Up to 12312150,5 to 0,8
13 to 20325401 to 1,5
21 to 30440501,2 to 2,2
31 to 40450501,8 to 3
41 to 50475502,2 to 3,2

Recommended cuttings

To cut antitwisting wire ropes, we recommend cutting by electric resistance or by welding.

Cables de Acero

Calibration

For calibration, the measuring device must be properly used.